LV-105EI/50Hz
(photo at right is of the 60 Hz unit) |
![]() |
Major Features
GENERATOR
|
ENGINE PACKAGE
|
![]()
| MODEL | -- WATTS ---- MAX |
- WATTS --- RATED |
VOLTS | AMPS RATED |
HERTZ | PHASE | WIRE | ---
ENGINE ----Power Rating |
START |
| LV105EI/50Hz | 8,333 | 7,915 | 220 | 33 | 50 | 1 | 4 | 670 cc Honda | ELECTRIC KEY START |
Page 2 Available as a 60 Cycle Also
MODEL |
STARTING METHOD |
NET (CM) |
PACKAGED (CM) |
NET |
PKG. |
CUBIC |
||||
L |
W |
H |
L |
W |
H |
|||||
| LV105EI/50Hz | ELECTRIC KEY START | 76.2 | 61 | 62.9 | 77.5 | 62.2 | 63.5 | 122 | 127 | 0.30 |

| STANDARD FEATURES |
| |
| receptacle --- |
| lock 220 volt receptacle --- |
| with "G.F.I.", Ground Fault
Interrupters --- |
| |
| --- |
| --- |
| |
| |
|
. Note: additional charge required for a single unit 50 cycle order |
ENGINE FEATURES Available as a 60 Cycle Also
MAKE |
............. | Honda GX670 670 cc 3000 R.P.M. |
| TYPE | ............. | 4 cycle, V-Twin cylinder, OHV air cooled. |
| LUBRICATION | ............. | Full pressure lubrication. |
| AIR COOLED | ............. | Flywheel forces air through cylinder block. |
| CRANKSHAFT | ............. | Precision steel with ball bearings on both ends. |
| IGNITION SYSTEM | ............. | Transistorized Magneto. |
| ROTATION | ............. | Counterclockwise (viewed from power takeoff side). |
| CYLINDERS & CRANKSHAFT | ............. | Diecast aluminum with cast iron sleeve. |
| CYLINDER HEAD | ............. | Aluminum alloy with Stellite valve seats. |
| PISTONS | ............. | Aluminum. |
| PISTON RINGS | ............. | Chrome plated. |
| CONNECTING RODS | ............. | Forged aluminum. |
| VALVES | ............. | Exhaust (Stellite), intake (heat treated). |
| GOVERNOR | ............. | Adjustable mechanical type. |
| FUEL CONSUMPTION | ............. | 29.9 liters tank capacity, 4.9 liters per hour fuel consumption @ full load. |
| 2.9 liters per hour fuel consumption @ half load. | ||
| STARTING | ............. | Automatic decompression and electric key start. |
| OIL PROTECTION | ............. | Automatic low oil engine shutdown. |
HERCULES ELECTRIC GENERATOR SPECIFICATIONS
| TYPE | ............. | Two pole revolving field brushless excitation, self regulated, |
| water proof construction and directly connected to engine. | ||
| EXCITATION | ............. | Self excitation provided by an auxiliary phase closed on a heavy duty capacitor. |
| DIODES | ............. | Silicon rectifier, hermetically sealed, 1000 volts with surge suppressers (varister). |
| POWER FACTOR | ............. | Single phase rated at 100 % "Unity" power factor. |
| FREQUENCY REGULATION | ............. | Less than 1 Hz (+ / - 1% running loads) 4 Hz (5%), no load to rated load. |
| DISTORTION | Extremely low harmonic distortion suitable for all electronic applications. | |
| BEARING | ............. | Double shielded and sealed ball bearings. |
| COOLING | ............. | High volume direct drive centrifugal fan forces air through the electric generator, |
| discharging it at engine end. | ||
| RADIO FREQUENCY INTERFERENCE SUPPRESSION | ............. | Totally brushless design exceeds civilian and military applications. |
| INSULATION | ............. | Class H (Stator & Rotor) per NEMA MG1-1.65, epoxy varnish impregnation. |
| STATOR | ............. | Steel laminations with all copper double insulation wire, inserted into slots. |
| Epoxy impregnation with load taken directly from leads. | ||
| ROTOR | ............. | Unique "Skewed Rotor Winding Design." Steel laminations pressed on tapered |
| steel shaft with double insulated wire inserted into insulation slots, wedged in with | ||
| epoxy impregnation. Dynamically balanced. Short circuit.capacity - 300% | ||
| VOLTAGE REGULATION | ............. | + / - 1% running loads ( + / - 5% no load to load ). |
| All units are manufactured to the highest engineering standards consistent with the industry. ELECTRIC GENERATOR SELECTIONS: When selecting electric generator be sure that the unit takes care of present total requirements and your anticipated needs. Motor loads require 3 to 4 times the wattage (or amperage) ratings on nameplate. RATINGS: Ratings apply to altitudes up 300 meters, standard cooling normal ambients and gasoline fuel. Reduce ratings 3 1/2% for each 300 meters above sea level and 1% for each 5.5 degrees Celsius rise above 15 degrees Celsius. Please refer to the Safety link below. |
| Back to Home Page |
Contact / Order
Info |
| Generator Sizing
Information |
Generator Safety |
TESTIMONIALS & COMPANY
REFERENCES
|
|