LV-150VEIZ/50Hz
12,500 WATT |
![]() |
Major Features
GENERATOR
|
ENGINE PACKAGE
|
Special Note: All Multi-Fuel units offered as stationary
units only.
| MODEL | WATTS |
WATTS |
VOLTS |
AMPS |
HERTZ |
PHASE |
WIRE |
ENGINE |
START |
LV-150VEIZ/50Hz |
12,500 |
10,000 |
220 |
45.5 |
50 |
1 |
4 |
627 cc |
ELECTRIC |
Page 2. Reduce all power ratings 20% when operating using natural gas.
MODEL |
STARTING METHOD |
NET (CM) |
PACKAGED (CM) |
NET |
PKG. |
CUBIC |
||||
L |
W |
H |
L |
W |
H |
|||||
LV-150VEIZ/50Hz |
ELECTRIC KEY START |
76.2 |
61 |
76.2 |
77.5 |
62.2 |
77.5 |
159 |
172 |
0.30 |

| STANDARD FEATURES |
| receptacle --- |
| lock 220 volt receptacle --- |
| receptacles with "G.F.I.", Ground Fault Interrupters --- |
| Idle down package --- |
| spark plugs --- |
| Hour Meter & Voltage Meter |
ENGINE FEATURES
MAKE |
............. | DIAHATSU / Vanguard 627 cc 3000 R.P.M. |
| TYPE | ............. | 4 cycle, V-Twin cylinder, OHV air cooled. |
| LUBRICATION | ............. | Full pressure lubrication. |
| AIR COOLED | ............. | Flywheel forces air through cylinder block. |
| OIL COOLED | ............. | Radiator style oil cooler gives engine additional cooling capabilities. |
| OIL FILTER | ............. | Replaceable automotive type, spin on oil filter. |
| CRANKSHAFT | ............. | Precision steel with ball bearings on both ends. |
| IGNITION SYSTEM | ............. | Electronic Capacitive Discharge System. |
| ROTATION | ............. | Counterclockwise (viewed from power takeoff side). |
| CYLINDERS | ............. | Diecast aluminum with Nickel-Silicon plated cast iron sleeves. |
| CYLINDER HEAD | ............. | Aluminum alloy with Cobalt valve seats. |
| PISTONS | ............. | Aluminum. |
| PISTON RINGS | ............. | Chrome plated. |
| CONNECTING RODS | ............. | Forged aluminum. |
| VALVES | ............. | Cobalt valves. |
| GOVERNOR | ............. | Adjustable mechanical type. |
| FUEL CONSUMPTION | ............. | Gasoline @ full load... 6.3 liters per hour. |
| Gasoline @ half load... 4.5 liters per hour. | ||
| Natural gas @ full load... 6.2 cubic meters per hour. | ||
| Natural gas @ half load... 4.0 cubic meters per hour. | ||
| Liquid Propane gas @ full load... 11.8 liters per hour. | ||
| Liquid Propane gas @ half load... 7.4 liters per hour. | ||
| STARTING | ............. | Electric key start with automatic decompression and auxiliary recoil / pull start. |
| OIL FILTER | ............. | Replaceable automotive type, spin on oil filter. |
| OIL PROTECTION | ............. | Automatic low oil engine shutdown. |
HERCULES ELECTRIC GENERATOR SPECIFICATIONS
| TYPE | ............. | Two pole revolving field brushless excitation, self regulated, |
| water proof construction and directly connected to engine. | ||
| EXCITATION | ............. | Self excitation provided by an auxiliary phase closed on a heavy duty capacitor. |
| DIODES | ............. | Silicon rectifier, hermetically sealed, 1000 volts with surge suppressers (varister). |
| POWER FACTOR | ............. | Single phase rated at 100 % "Unity" power factor. |
| FREQUENCY REGULATION | ............. | Less than 1 Hz (+ / - 1% running loads) 4 Hz (5%), no load to rated load. |
| DISTORTION | ............. | Extremely low harmonic distortion suitable for all electronic applications. |
| BEARING | ............. | Double shielded and sealed ball bearings. |
| COOLING | ............. | High volume direct drive centrifugal fan forces air through the electric generator, |
| discharging it at engine end. | ||
| RADIO FREQUENCY INTERFERENCE SUPPRESSION | ............. | Totally brushless design exceeds civilian and military applications. |
| INSULATION | ............. | Class H (Stator & Rotor) per NEMA MG1-1.65, epoxy varnish impregnation. |
| STATOR | ............. | Steel laminations with all copper double insulation wire, inserted into slots. |
| Epoxy impregnation with load taken directly from leads. | ||
| ROTOR | ............. | Unique "Skewed Rotor Winding Design." Steel laminations pressed on tapered |
| steel shaft with double insulated wire inserted into insulation slots, wedged in with | ||
| epoxy impregnation. Dynamically balanced. Short circuit. capacity - 300% | ||
| VOLTAGE REGULATION | ............. | + / - 1% running loads ( + / - 5% no load to load ). |
| All units are manufactured to the highest engineering standards consistent with the industry. ELECTRIC GENERATOR SELECTIONS: When selecting electric generator be sure that the unit takes care of present total requirements and your anticipated needs. Motor loads require 3 to 4 times the wattage (or amperage) ratings on nameplate. RATINGS: Ratings apply to altitudes up 300 meters, standard cooling normal ambients and gasoline fuel. Reduce ratings 3 1/2% for each 300 meters above sea level and 1% for each 5.5 degrees Celsius rise above 15 degrees Celsius. Please refer to the Safety link below. Special Note: All Multi-Fuel units offered as stationary units only. |
| Back to Home Page
|
Contact
/ Order Info
|
| Generator Sizing
Information
|
Generator Safety
|
TESTIMONIALS & COMPANY
REFERENCES
|
|